Ali Tube Fixed Wiring Cable BS8436

Download Data Sheet

Designed for use in walls, partitions, and building voids where the risk of damage or penetration from nails and screw fixings exists. This protected fixed wiring cable, with an aluminum tube screen, offers mechanical shock protection, making it suitable for ring main power and lighting applications. It serves as an alternative to singles in conduit or armoured cables and can be installed in air, trunking, or closed systems, as well as in thin partitions and building voids when connected to a suitable protective device.

Download Here

Designed for use in walls, partitions, and building voids where the risk of damage or penetration from nails and screw fixings exists. This protected fixed wiring cable, with an aluminum tube screen, offers mechanical shock protection, making it suitable for ring main power and lighting applications. It serves as an alternative to singles in conduit or armoured cables and can be installed in air, trunking, or closed systems, as well as in thin partitions and building voids when connected to a suitable protective device.

Conductor

Plain Copper

Stranding

Class 2

Insulation

XLPE

Collectivescreen

Collective Aluminium Mylar

Metallicscreen

Aluminium Wire Screen

Outersheath

LSZH

Colour

Black, White

Voltage

500V

Ratingtables

4D5

Identification

2 core: Brown, Blue 3 Core: Brown, Black, Grey 4 Core: Brown, Black, Grey, Blue

Bendingradius

9 x Overall Diameter

Temperature

90°C

Area sq mm Max DC Resistance ohms/Km at 20°C Nominal AC resistance ohms/km at 90°C at 50Hz Inductive reactance ohms/km at 50Hz Max continuous conductor operating temperature °C Short circuit rating in kA for 1 second
1.5 12.1 15.3 0.100 90 0.21
2.5 7.41 9.43 0.097 90 0.35
4 4.61 5.86 0.092 90 0.57
6 3.08 3.93 0.088 90 0.85

ERA Technology Results Earthing capabilities of the screen under nail penetration test conditions: The results have shown the screen on Guardian can withstand a fault current of over 200A, which is the fault current required to operate a 40A Type B circuit breaker instantaneously. Impact resistance tests: Guardian passed these conditions and eventually reached the level of a 1.0kg weight dropped from a height of 0.8m, at ambient temperatures thus exceeding the requirements of fire performance cables.

BATT Part No White Core Nominal cross sectional area of conductor Approx overall diameter Weight
12022 2 1.5 9.6 105
12023 2 2.5 10.7 140
12024 2 4 11 209
12038 2 6 13.2 260
12025 3 1.5 10.2 140
12026 3 2.5 11 184
12027 3 4 13.2 267
12040 3 6 14.2 330
12028 4 1.5 11 160
12029 4 2.5 13.2 258
12030 4 4 13.8 320
12054 4 6 15.7 433
Batt Part No. Core Size Colour/Reference
12022 2 1.5 White
12033 2 1.5 Black
12023 2 2.5 White
12034 2 2.5 Black
12042 2 4 Black
12024 2 4 White
12024 2 4 White
12038 2 6 White
12025 3 1.5 White
12035 3 1.5 Black
12026 3 2.5 White
12036 3 2.5 Black
12027 3 4 White
12040 3 6 White
12049 3 6 Black
12028 4 1.5 White
12031 4 1.5 Black
12029 4 2.5 White
12032 4 2.5 Black
12051 4 4 Black
12030 4 4 White
12056 3 6 Black
12051 4 4 Black

The information in this datasheet is for guidance only and subject to change without liability. Images provided are representations; actual cable dimensions may vary due to manufacturing tolerances.

For technical product questions,
get in touch with our experts.