Cables compliant with Def Stan 61-12 Part 6 specifications, offered in Types 1, 2, and 3, are engineered for internal wiring within electronic equipment in military and industrial environments. Initially crafted for defense purposes, Def-Stan cables have evolved into vital components in rugged industrial settings, avionic controls, and computer data processing units. With resistance to fuel and mineral-based fluid contamination, these cables ensure uninterrupted performance even in the most challenging conditions.

Download Here

Cables compliant with Def Stan 61-12 Part 6 specifications, offered in Types 1, 2, and 3, are engineered for internal wiring within electronic equipment in military and industrial environments. Initially crafted for defense purposes, Def-Stan cables have evolved into vital components in rugged industrial settings, avionic controls, and computer data processing units. With resistance to fuel and mineral-based fluid contamination, these cables ensure uninterrupted performance even in the most challenging conditions.

Conductor

Tinned Copper

Insulation

PVC

Colour

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Brown, Pink, Yellow, Green

Voltage

1000V

Temperature

-15 °C to +85 °C

Standards

Defence Standard 61-12 Part 6 BS4808

No of cores Nominal cross sectional area (mm2) Construction conductor (mm) Minimum thickness of insultaton (mm) Radial thickness of insulation (mm) Minimum overall diameter (mm) Maximum overall diameter (mm) Weight (kg/km)
1 0.22 7/0.2 0.25 0.3 1.1 1.3 3.13
1 0.50 16/0.2 0.25 0.3 1.45 1.65 6.11
1 0.75 24/0.2 0.4 0.4 1.95 2.15 9.85

 

BATT Part No Red BATT Part No Black BATT Part No Green BATT Part No White BATT Part No Pink BATT Part No Blue BATT Part No Violet BATT Part No White/Blue BATT Part No Violet/Red BATT Part No Brown BATT Part No White/Orange BATT Part No Yellow BATT Part No Grey BATT Part No Orange BATT Part No Green/Yellow No of cores Nominal cross sectional area (mm2)
34001 34002 34003 34005 34007 34008 34082 34210 - - - - - - - 1 0.22
34013 34014 34017 34015 34018 34016 34086 - 34055 34068 34243 34083 34084 34085 34087 1 0.50
34088 34020 34095 34091 34093 34090 34097 - - 34089 - 34092 34094 34096 34098 1 0.75

ELECTRICAL CHARACTERISTICS

Nominal cross sectional area (mm2) Maximum DCR at 20 °C Current carrying capacity at 70 °C
0.22 88 1.4
0.50 38.2 3
0.75 25.5 4.5

 

Batt Part No. Core Size Colour/Reference
34001 1 0.22 Red
34002 1 0.22 Black
34003 1 0.22 Green
34005 1 0.22 White
34007 1 0.22 Pink
34008 1 0.22 Blue
34082 1 0.22 Violet
34210 1 0.22 White/Blue
34055 1 0.50 Violet/Red
34068 1 0.50 Brown
34243 1 0.50 White/Orange
34083 1 0.50 Yellow
34084 1 0.50 Grey
34085 1 0.50 Orange
34086 1 0.50 Violet
34087 1 0.50 Green/Yellow
34013 1 0.50 Red
34014 1 0.50 Black
34015 1 0.50 White
34016 1 0.50 Blue
34017 1 0.50 Green
34018 1 0.50 Pink
34020 1 0.75 Black
34088 1 0.75 Red
34089 1 0.75 Brown
34090 1 0.75 Blue
34091 1 0.75 White
34092 1 0.75 Yellow
34093 1 0.75 Pink
34094 1 0.75 Grey
34095 1 0.75 Green
34096 1 0.75 Orange
34097 1 0.75 Violet
34098 1 0.75 Green/Yellow