Helios Stainless Steel Fire Performance Cleats

Download Data Sheet

CMP Helios Stainless Steel Fire Performance Cleats for use with fire performance cables. These fire resisting supports help to maintain the electrical systems integrity for any critical circuits during an emergency situation to enable safe evacuation.

Download Here

CMP Helios Stainless Steel Fire Performance Cleats for use with fire performance cables.

The Helios Standard Duty, One Bolt, High Temperature Fire Rated Stainless Steel single cable cleat is a fabricated metallic cleat which has been designed, constructed, and tested in accordance with the International Standard ‘Cable Cleats for Electrical Installations’ (IEC 61914).

These Fire Rated cable cleats can be used with fire performance cables to ensure the safe retention and securing of single cables in the event of a wiring system being affected by fire. These fire resisting supports help to maintain the electrical systems integrity for any critical circuits during an emergency situation to enable safe evacuation. The cable cleat is fabricated from Stainless Steel 316L making it suitable for both indoor and outdoor applications.

The Helios High Temperature Stainless Steel 316L cable cleat is available in eleven sizes suitable for cable diameters of 10mm up to 65mm. The cable cleat has an M10 clearance hole for securing it to a mounting surface.

 

Features:

  • Fabricated Stainless Steel 316L
  • Operating temperature -60°C to +250°C
  • Surpasses requirements of Fire testing BS5839 / BS8491 / EN50200 / BS8434 / AS-NZS 3013 (1,200°C) (Fire, shock & water)
  • 10 – 65mm cable range take in 11 sizes
  • Single bolt fixing design
  • Can be stacked
  • Corrosion resistant
Parallel Formation

One Short Circuit 600mm Fixed Cleat Centres

100mm Cable Centres

Two Short Circuit 600mm Fixed Cleat Centres

100mm Cable Centres

0.1 sec 0.1 sec
60kA Peak 60kA Peak
29kA RMS 29kA RMS
BS 5839 ‘Fire detection and fire alarm systems for buildings. Code of practice
for design, installation, commissioning and maintenance of systems
in non-domestic premises’
States that “Methods of cable support should be non-combustible and such
that circuit integrity will not be reduced below that afforded by the cable used, and should withstand a similar temperature and duration to that of the cable,
while maintaining adequate support”
To adhere to this BSI standard fire rated Cable Cleats must be used to support
the cable in the event of a fire.

 

Batt Part No.
 
CMP Reference
 
Cable OD Range:
 
Dimensions (mm) Fixing Hole Weight
Width Height Depth Ø (g)
90160 FPC1013 10-13mm 38 19 40 1 x M10 88
90161 FPC1316 13-16mm 41 22 40 1 x M10 103
90162 FPC1619 16-19mm 45 25 40 1 x M10 114
90163 FPC1923 19-23mm 50 29 40 1 x M10 128
90164 FPC2327 23-27mm 55 33 40 1 x M10 143
90165 FPC2732 27-32mm 61 38 40 1 x M10 165
90166 FPC3238 32-38mm 67 44 40 1 x M10 182
90167 FPC3846 38-46mm 74 52 40 1 x M10 210
90168 FPC4651 46-51mm 80 57 40 1 x M10 233
90169 FPC5157 51-57mm 86 63 40 1 x M10 252
90171 FPC5765 57-65mm 94 71 40 1 x M10 274

Batt Part No. Cable OD Range Material CMP Reference
90160 10-13mm Stainless Steel FPC1013
90161 13-16mm Stainless Steel FPC1316
90162 16-19mm Stainless Steel FPC1619
90163 19-23mm Stainless Steel FPC1923
90164 23-27mm Stainless Steel FPC2327
90165 27-32mm Stainless Steel FPC2732
90166 32-38mm Stainless Steel FPC3238
90167 38-46mm Stainless Steel FPC3846
90168 46-51mm Stainless Steel FPC4651
90169 51-57mm Stainless Steel FPC5157
90171 57-65mm Stainless Steel FPC5765